The Water Line On A CoA: What LOD Really Measures

A buyer we work with in Ahmedabad ran into this last year. Two lots, same product, same grade. Lot one reported water at 0.3 percent by loss on drying. Lot two came back at 0.8 percent, also by loss on drying. He recalculated his charge weight for the second lot, adjusted the ratio on his process sheet, and released the batch. Six weeks later his own QC lab ran the same drums on a Karl Fischer titrator: 0.35 percent.

The powder had never been wet. The LOD number had simply been reporting something else — residual solvent from the drying step, mostly — and he had spent an afternoon chasing a moisture problem that did not exist.

Questions like his arrive at our desk every month, and the confusion underneath them is the same every time: two test methods, both printed on certificates, both loosely called “water content”, measuring different things. The distinction is not academic.

It decides how you calculate a charge, whether you accept or reject a lot, and what your specification should actually say. This article walks through what each method covers, where the numbers diverge, and what a buyer can settle at a desk in a few minutes.

What Loss On Drying Actually Measures

Despite the name, loss on drying does not measure water. It measures mass. A sample is heated — conventionally around 105 degrees Celsius, sometimes under vacuum — until its weight stops changing, and the difference is reported as a percentage. Whatever left the sample counts: water, yes, but also residual solvents, volatile organic impurities, and anything else light enough to escape at that temperature.

This is why the line on a certificate is sometimes called “loss on drying” rather than “moisture”. The label is more honest than the way it gets read. On an intermediate that was the last thing to leave the drying step, the loss is dominated by whatever the process shed last.

If the final isolation was a solvent recrystallization and the drying endpoint was reached quickly, the remaining volatiles can be a meaningful share of that number. What the residual solvents line leaves unsaid matters here, because the solvent content and the drying loss are not independent figures — they are two views of the same volatiles, taken by different methods.

None of this makes LOD a bad test. It is fast, cheap, needs no reagents, and for many intermediates it is a perfectly adequate process control. The trouble starts only when somebody converts it into a water number and does arithmetic on top of it.

What Karl Fischer Actually Measures

Karl Fischer titration is a chemical measurement, not a physical one. The reagent reacts specifically with water, and the instrument quantifies how much reagent was consumed. Solvents that would happily evaporate at 105 degrees do not react with the reagent, so they do not appear in the result. What comes out is water — with caveats.

The first caveat is method variant. Volumetric KF suits higher water contents; coulometric KF suits trace levels. For a typical intermediate sitting below one percent, coulometric is the more natural fit, and a supplier reporting volumetric results at 0.2 percent is worth a question, because near the bottom of its range the volumetric method loses precision. The second caveat is sample solubility.

Water locked inside a crystal lattice or bound to the molecule can resist the reagent unless the method includes an oven attachment or a solubilizer. A KF result is only as good as the method development behind it, and the certificate should say which variant was run.

The third caveat rarely appears in buyer conversations, but it decides real cases: KF measures water in all its forms, including water of crystallization. For a hydrate, the “correct” water content is not zero. The specification is where that expectation gets written down, and a buyer who reads a hydrate’s KF result against a non-hydrate expectation will reject perfectly good material — or accept material whose crystal form has quietly shifted.

The Two Numbers Side By Side

 

Loss on drying (LOD)

Karl Fischer (KF)

What it detects

Everything volatile at the test temperature: water plus residual solvents and other volatiles

Water only, including bound and crystallized water when the method allows

How it detects it

Weighing — mass lost on heating

Chemical reaction — reagent consumed specifically by water

Typical reporting

A single percentage, sometimes with the temperature noted

A percentage or ppm value, with the variant (volumetric / coulometric) normally stated in the method

Where it misleads

When residual solvent inflates the figure, or when it is converted into a charge calculation as if it were pure water

When the sample matrix hides water from the reagent, or when a hydrate is judged against an anhydrous expectation

Best use

Process control, batch consistency, quick release checks

Water-critical chemistry, hydrates, low-level moisture, arbitration between labs

The table has a quiet implication worth spelling out: the two methods are not competitors so much as answers to different questions. LOD answers “how much mass did this sample shed when heated”. KF answers “how much water does this sample contain”. A certificate that reports both is not being redundant; it is handing you the difference between them, and that difference is itself information — usually a rough picture of the volatiles that are not water.

Why The Two Numbers Disagree

Three situations produce a gap between LOD and KF on the same batch, and each one tells you something different.

The first is residual solvent. A drying loss of 0.8 percent against a KF result of 0.3 percent means roughly half a point of the loss was not water. On a batch fresh from a solvent-based isolation this is common and usually benign, but the number does not belong in a moisture calculation. The Ahmedabad case at the top of this article was exactly this pattern, and the correction was arithmetic, not manufacturing.

The second is bound water. Some intermediates hold water in ways that 105 degrees will not release within the test window, so LOD under-reports relative to KF. Hydrates are the textbook case; certain salts and polymers behave the same way. Here the KF figure is the truthful one, and an LOD spec written too tightly will fail batches that are, in water terms, perfectly fine.

The third is method drift rather than the sample: the LOD oven temperature or endpoint criterion changed between the method version on the certificate and the one the specification assumes. This is the least obvious and the most annoying, because both numbers are “correct” and neither describes the material the buyer thinks he is comparing. Which of the dates on a certificate actually decide anything includes the method edition, for precisely this reason — a water comparison across certificates is only valid when the methods behind the numbers match.

As-Is Versus Dried Basis

A second trap sits next to the first. Certificates report assay and water on different bases: results are sometimes calculated “as is” — on the material exactly as it sits in the drum — and sometimes “on the dried basis”, meaning the calculation normalizes out the volatile loss first. The same physical batch can produce an assay of 98.5 percent as-is and 99.6 percent on the dried basis, and both numbers are correct.

Charge weight is where buyers get caught. If your process charges 100 kilograms of material and the water figure you use is a dried-basis number while your weighing is obviously as-is, the correction goes in the wrong direction.

The rule of thumb is short: weigh as-is, correct with as-is. Any conversion between the bases should happen once, deliberately, in the calculation sheet — not implicitly, by copying whichever water number appeared first on the certificate. The discipline of reading a certificate line by line exists because of exactly these small, silent mismatches between what a line says and what a calculation assumes.

What To Ask, And What The Specification Should Say

Desk-level questions settle this topic faster than any argument. When a certificate reports water, four questions cover most of the risk:

Which method ran — LOD, volumetric KF, or coulometric KF? At what temperature and to what endpoint, for an LOD? Which method edition, and does it match the specification’s assumption? And is the reported basis as-is or dried? A supplier who answers these without hesitation has almost certainly run the test properly; hesitation itself is information.

The specification should be equally plain. Name the method, not just the limit — “water content ≤ 0.5 percent by Karl Fischer, coulometric” is enforceable, while “moisture ≤ 0.5 percent” invites each lab to substitute whatever instrument is nearest. State the basis. For a hydrate, define the expected range rather than a floor of zero. These are the same principles used when acceptance criteria are set for any other line on the document: a specification that names its method cannot be argued with by convenience.

One more clause belongs in the quality agreement rather than the spec: what happens when buyer and supplier water results disagree. Because KF is the reference method for water, the sensible default is that a dispute escalates to KF — ideally coulometric, run by a third party if neither side’s result convinces the other. Writing this down before a dispute is worth an hour; deciding it during one is worth a week. What independent laboratory testing proves, and what it does not fits this clause directly, since a third-party KF result is among the cleanest uses of that route.

When Water Numbers Move Between Lots

Single-batch judgment is only half the value. Water content is one of the most sensitive trend indicators a buyer has, because it reacts to things the buyer cannot see: the supplier’s drying endpoint discipline, ambient humidity in the packing area, how long drums sat in a warehouse, and whether the liner in the drum was sealed properly.

So read the line across lots, not just within one. Water is also one of the few lines where the story starts before the drums are even sealed — ambient humidity, packing-room dwell time and liner condition all leave fingerprints — which is why the check that happens before loading catches moisture problems earlier than any receiving-file test can. A KF series of 0.28, 0.31, 0.33 percent is a stable process with noise.

A series of 0.25, 0.55, 0.20 percent is a process question, and the question is worth asking before the third lot ships rather than after the second fails your incoming check. How consistency is judged between batches applies the same logic to every line on the certificate; water is simply the line where a trend shows up earliest, because it responds to handling as much as to chemistry.

When a result does land outside the limit, the route is the same as for any other out-of-limits line: the supplier investigates, and the buyer decides whether the deviation is explainable or structural. What an out-of-specification result obliges the supplier to do covers the full procedure — the one adjustment here is that water disputes specifically get re-tested by KF, not by repeating the same LOD method that produced the questionable figure.

The Desk Routine, In Order

Condensed: first, identify the method behind the water line and the basis it is reported on. Second, if the certificate carries both LOD and KF, read the gap as volatiles rather than as an error. Third, convert to charge weight using as-is figures, once, deliberately. Fourth, check that the method edition matches the specification’s assumption. Fifth, place this certificate’s water figure into the trend across recent lots.

Five minutes in total, and the Ahmedabad problem from the opening — a moisture adjustment made against a number that was never moisture — becomes impossible to repeat. The powder was fine the whole time. The reading was not.

 

Scroll to Top

Contact us to Get the Best Product Solution